Radon Testing | Radon Mitigation |  MD VA DC | 240-224-0577
☎ 240-224-0577 | ✉ [email protected]

Measurement outcomes Impacted by following things (avoid false low or false high results):

1.Closed Building Conditions Rule. Radon gas is constantly decaying and re-occurring. It takes only 12 hours to reach Dynamic Equilibrium , RDP levels to stabilize once the radon rate into a building has been altered (ex. open doors, windows).

Closed Building Conditions:

  • Windows Must be kept Closed for duration of test
  • Doors maybe be opened for momentary exit/entry only
  • Normal HVAC settings 72 degree +/- 5 degree

2. Decay Factors is especially important in passive devices like radon testing kit. Passive charcoal devices(Activated Carbon) must be shipped to the lab for analysis. During this “transit” time (from home to lab),the radon that has adsorbed onto the charcoal continues. To decay. Therefore, Start/Stop times and prompt shipping is very important. Start/Stop times are important in all radon measurements because remember, 1.0 pCi/L of radon decays at 2.22 disintegrations per minute. If the start/stop times are incorrect, the overall average will be incorrect. And test will be VOID.

3. Weather Conditions. Do not test during Severe weather conditions. The national weather services defines a severe storm as a storm that generates wind of 58 mph and or 3/4 inch diameter hail. However IEMA and ANSI define sever storms or periods of sustained winds of 30mph or more. The 96 hours rule mandatory for short term measurements of less then 96 h must not be conducted during severe wind conditions.

4. Diurnal Cycles

5. Background Radiation

6.Thoron

7. Device Consideration

8. Protocol and Methods

Which one Radon Testing Kit should I pick ?

Passive Device: Radon Testing Kit

Activated Carbon (AC)

  • Radon gas diffuses into the device
  • Radon decays into RDPs
  • sensitive to humidity and airflow
  • sensitive to temperature
  • RDPs adsorb onto carbon granules by molecular diffusion
  • Gammas(RDPs) are measured (Bi214 and Pb 214)
  • Exposed for 2-7 days
  • Analyzed at the lab by weighing the device
  • no tamper prevention
  • must be returned to the lab FAST( if not analyzed promptly, radon and RDPs may decay beyond the LLD(lower limit of detection and test will be void.
  • Results biased to last 12-24 hours of test

Activated Carbon (AC)

  • Results biased to last 12-24 hours of test
  • Sensitive to humidity and airflow
  • 2-5 days test
  • no tamper prevention
  • must be returned to the lab FAST( if not analyzed promptly, radon and RDPs may decay beyond the LLD(lower limit of detection and test will be void.
  • Sensitive to temperature
Liquid Scintillation Vials(LS)

Liquid Scintillation Vials(LS)

  • Alpha Scintillations
  • Small vial with 4-5 grams of activated charcoal
  • RDPs adsorbs onto Charcoal
  • at the lab, charcoal is infused with liquid scintillation fluid
  • must wait 4 hours before analysis can be done
  • It takes 4 h for radon to equilibrate with its RDPS(Secular equilibrate)

Alpha Track Detectors(AT)

  • Alpha-sensitive plastic chip or film
  • Filter allows only radon, not RDP’s, to passively diffuse into chamber
  • RDPs emit alphas that pit the chip/film and leave tracks
  • true integrated device
  • Calibrated by tracks per unit area per pCi/L per day
  • Not affected by temperature, humidity or airflow
  • Analysis by lab
  • Normal living conditions during test
  • large precision error at low radon levels
  • Low Sensitivity
  • Long term 9o days to 1 year
E-Perm

Electret Ion Chambers (ES-Short term 50cc, EL – Long term 200cc)

  • Measures Alphas
  • Radon Passively diffused into chamber ( Ion pairs created when RDP alphas kick out electrons from oxygen and nitrogen atoms
  • onsite analysis, no need to send to the lab
  • reusable electret reusable
  • Not affected by temperature, humidity, air flow
  • can be used to measure radon in water
  • can be used for long term or short term radon testing
  • sensitive to background gamma radiation
  • electrets can lose voltage in storage
  • you will need voltmeter
  • high radon levels or long exposure may deplete electret beyond its capacity

Radon gas is measured in picocuries per liter (pCi/L)

RADON MITIGATION: Do You Really Need It? This Will Help You y Decide!

Radon gas is invisible, and it doesn’t have any smell or taste, but it accumulates in the basement due to its wavy weight. Radon usually does not present a health risk outdoors because it is diluted in the open air.

Radon is something that we have known about for more than a century. It is something we have known for about two generations as a killer. And what is dangerous about it, as it arises from the radium minerals found in the soil under many homes foundations. This gas is radioactive. It emits the radiation called Alfa particle radiation. Which is very similar to that one we accounted up in space. Alfa particles move very quickly, indeed half the speed of light. It has enough energy to put a dent in a piece of plastic. Imagine what that does inside your body. All of us are born with nice untacked DNA. After Alfa particle gets inside of our body, it reacts with water that comprises our cells and turning it into highly reactive oxygen, which then reacts and breaks part our DNA, generating mutation which drives cancer.

Radon alpha radiation is much more dangerous than x-ray at the dental office. It transforms our genetic cells into cancer inside us. Radon is classified by health authorities as a category one cancer-causing agent.

NRPP Certified radon inspector Katsiaryna Holder from Alfa Air Agency says: “Radon gas comes out of the ground and stays in your front lawn dilutes to almost nothing instantaneously, but if a human makes the airtight structure, like home, then radon gas accumulated, to a very hazards concentration. While radon is a natural thing, what is unnatural is the way our building is concentrated with radon to a very hazardous level. We can do a radon test. For example, with an Alpha track detector. Alphas that pit the film and leave tracks will be calculated under the microscope in a lab. That will tell us how much radon is in the house.

Alpha particles  on radon test results

The higher the radon concentration and exposure, the sooner action should be taken to reduce the radon level to as low as possible. The EPA recommends taking steps to lower radon levels if test results show levels 4.0 pCi/L or higher. Experienced radon mitigation provider Giorgi Rodonaia says, “Radon is a health hazard with a simple solution. EPA has developed proved guidelines and techniques to safely remove radon from the house up to 99% “. Rodonaia Holding is a DC metropolitan area radon mitigation contractor who saves lives, one home at a time. People can avoid radon exposure, limit their chances of damaged lung tissue and lung cancer.

EPA, United States Environmental Protection Agency has created a map that indicates where people are more likely to be exposed to radon in indoor air. Darker colors indicate a higher risk.

Pierre Dubois, who was recently diagnosed with lung cancer, said that radon is a bit like COVID-19. “The only way to know if you have it is by testing.”

EPA Map of Radon Zones USA

Alfa Air Agency announced 30 free radon test kits give away across DC metropolitan area, zone 1. Americans should know they can take control of their risk from radon.

Source: Alfa Air Agency

Contact : Info@AlfaAirAgency  to claim your radon free test kit

Copyright©2018-2023 Alfa Air Agency,LLC | All rights reserved| 200 Wisconsin ave, Ste 1012, Bethesda MD 20814| tel:240-224-0577