Radon Testing | Radon Mitigation |  MD VA DC | 240-224-0577
☎ 240-224-0577 | ✉ [email protected]

1 out of 15 homes have High Radon level

Certified Radon Testing and Mitigation services in MD, VA, DC

12 Steps to install radon mitigation in a day

Radon mitigation starts with reviewing the building structure and previous radon measurements.

  1. Walk Through : to determine the potential radon entry routes and establish the appropriate mitigation strategy.
  2. Communication Tests: If a sub-slab depressurization system is considered as possible choice of systems then communications test should be performed if sub-slab soil conditions are unknown.
  3. System Goals and Design : A radon reduction system shall be designed as an integral part of a dwelling, minimize noise and aesthetic impact on the structure.
  4. For SSD system piping PVC or ABS shall be used
  5. Radon Collection point: A min of one half cubic foot of sub-slab material shall be excavated at each suction point.
  6. Number of Suction points shall be determined by communication available throughout the sub-soil, the number of separate slabs that are significant radon sources and do not communicate with other slabs.
  7. Fan shall be sized to provide adequate vacuum and air flow characteristics for each mitigation installation.
  8. Exhaust location shall be at list 12″ above the roof line and at list 10 feet from any vent, window, or openings that are less then 2 ft below the exhaust point.
  9. Electrical connection: if the fan capacity exceeds 50% of the circuit capacity, then fan shall be wired with a dedicated circuit. There shall be electrical disconnect for the fan for homeowner and service use.
  10. Sealing cracks and non-functioning openings that emanate soil gas.
  11. Open cinder and concreate block cores and voids should be sealed
  12. System Monitoring: Each depressurization system shall include a vacuum indicator, a pressure U-tube manometer .

In conclusion, radon mitigation system installation is a complex process. It requires experience and knowledge of hazardous materials, basic building design, electrical wiring, construction materials. In addition, you should understand building pressurization/depressurization conditions and measurement procedures, radon reduction techniques. A licensed and experienced radon mitigation provider can install one SSD mitigation system in about 8 hours. For a homeowner, without proper tools and knowledge, this project can be a challenging, but rewording task.

EPA logo